Zugriffsnummer 11233
Dokumenttyp Konferenzartikel in Zeitschrift Freier Zugang
Peer Review mit Peer Review
Sprache Englisch
Titel Development of transfer standard devices for ensuring the accurate calibration of ultrasonic physical therapy machines in clinical use
Autor(in); Institution
Hekkenberg, Rob T.; TNO Prevention and Health, Leiden, THE NETHERLANDS
Richards, Adrian; National Measurement Laboratory, CSIRO, Sydney, AUSTRALIA
Beißner, Klaus; 1.6, Schall, PTB-Braunschweig
Zeqiri, Bajram; National Physical Laboratory (NPL), Teddington, UK
Prout, Glen; National Measurement Laboratory, CSIRO, Sydney, AUSTRALIA
Cantrall, Chris; National Measurement Laboratory, CSIRO, Sydney, AUSTRALIA
Bezemer, R. A.; TNO Prevention and Health, Leiden, THE NETHERLANDS
Koch, Christian; 1.6, Schall, PTB-Braunschweig
Hodnett, Mark; National Physical Laboratory (NPL), Teddington, UK
Quelle/Jahr Journal of Physics: Conference Series: 1 (2004), 99 - 104
ISSN 1742-6588 (PRINT) ; 1742-6596 (ONLINE)
DOI
URL
Verlag Bristol: IOP
Konferenzangaben Advanced Metrology for Ultrasound in Medicine at NPL, Teddington, 27- 28, April, 2004, UK
Zusammenfassung Physical therapy ultrasound is widely applied to patients. However, many devices do not comply with the relevant standard stating that the actual power output shall be within ± 20% of the device indication. Extreme cases have been reported: from delivering effectively no ultrasound or operating at maximum power at all powers indicated. This can potentially lead to patient injury as well as mistreatment. The present European (EC) project is an ongoing attempt to improve the quality of the treatment of patients being treated with ultrasonic physical-therapy. A Portable ultrasound Power Standard (PPS) is being developed and accurately calibrated. The PPS includes: Ultrasound transducers (including one exhibiting an unusual output) and a driver for the ultrasound transducers that has calibration and proficiency test functions. Also included with the PPS is a Cavitation Detector to determine the onset of cavitation occurring within the propagation medium. The PPS will be suitable for conducting in-the-field accreditation (proficiency testing and calibration). In order to be accredited it will be important to be able to show traceability of the calibration, the calibration process and qualification of testing staff. The clinical user will benefit from traceability because treatments will be performed more reliably.
Kostenfreier Zugang Freier Zugang

Zitierung

Hekkenberg, R. T., Richards, A., Beißner, K., Zeqiri, B., Prout, G., Cantrall, C., Bezemer, R. A., Koch, C., & Hodnett, M. (2004). Development of transfer standard devices for ensuring the accurate calibration of ultrasonic physical therapy machines in clinical use. Journal of Physics: Conference Series, 1, 99–104. https://doi.org/10.1088/1742-6596/1/1/024

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag