| Zugriffsnummer | 11048 |
| Dokumenttyp | Konferenzartikel in Zeitschrift |
| Sprache | Englisch |
| Titel | Measurement of neutron fluence spectra up to 150 MeV using a stacked scintillator neutron spectrometer |
| Autor(in); Institution |
Brooks, F. D.; University of Cape Town, Physics Department, Rondebosch, SOUTH AFRICA
Allie, M. S.; University of Cape Town, Physics Department, Rondebosch, SOUTH AFRICA
Buffler, A.; University of Cape Town, Physics Department, Rondebosch, SOUTH AFRICA
Dangendorf, Volker; 6.5, Neutronenstrahlung, PTB-Braunschweig
Herbert, M. S.; University of Cape Town, Physics Department, Rondebosch, SOUTH AFRICA
Makupula, S. A.; University of Cape Town, Physics Department, Rondebosch, SOUTH AFRICA
Nolte, Ralf; 6.4, Ionenbeschleuniger und Referenzstrahlungsfelder, PTB-Braunschweig
Smit, F. D.; iThemba Laboratory for Accelerator-Based Sciences, Somerset West, SOUTH AFRICA
|
| Quelle/Jahr | Advances in nuclear particle dosimetry for radiation protection and medicine : Ninth Symposium on Neutron Dosimetry, Aula Conference Centre, Delft University of Technology, Delft, The Netherlands 28 September to 3 October 2003. Radiation Protection Dosimetry: 110 (2004), 1-4, 151 - 155 |
| Herausgeber(in) |
Zoetelief, J.; Delft University of Technology, Interfaculty Reactor Institute, Delft, THE NETHERLANDS
|
| ISSN | 0144-8420 |
| ISBN | 0-19-856713-8 |
| Verlag | Oxford [u.a.]: Oxford University Press |
| Konferenzangaben | Ninth Symposium on Neutron Dosimetry, Delft, 28, September to 3, October 2003, The Netherlands |
| Freie Schlagworte | Neutron Spectrometry ; Time-Of-Flight ; Neutron Fluence ; Stacked Scintillation Detector |
| Zusammenfassung | A stacked scintillator neutron spectrometer (S3N) consisting of three slabs of liquid organic scintillator is described. A pulsed beam providing a broad spectrum of neutron energies is used to determine the detection efficiency of the spectrometer as a function of incident neutron energy and to measure the pulse height response matrix of the system. Neutron spectra can then be determined for beams with any kind of time structure by unfolding pulse height spectra measured by the S3N. Examples of fluence spectrum measurements in the energy range 20-150 MeV are presented. |
Zitierung
Brooks, F. D., Allie, M. S., Buffler, A., Dangendorf, V., Herbert, M. S., Makupula, S. A., Nolte, R., & Smit, F. D. (2004). Measurement of neutron fluence spectra up to 150 MeV using a stacked scintillator neutron spectrometer. Radiation Protection Dosimetry, 110(1-4), 151–155.