Titel New multi-frequency method for the determination of the dissipation factor of capacitors and of the time constant of resistors
Autor(in); Institution
Ramm, Günther; 2.1, Gleichstrom und Niederfrequenz, PTB-Braunschweig
Moser, Harald; 2.1, Gleichstrom und Niederfrequenz, PTB-Braunschweig
Quelle/Jahr 2004 Conference on Precision Electromagnetic Measurements Digest:(2004), 93 - 94
ISBN 0-7803-8493-8
Berichtsnummer 04CH37570
Verlag Piscataway, NJ: IEEE
Konferenzangaben Conference on Precision Electromagnetic Measurement (CPEM), London, 27, June - 02, July, 2004, UK
Freie Schlagworte multy-frequency method ; dissipation factor of capacitors ; time constant of the ac resistor
Zusammenfassung A new method for the simultaneous determination of the dissipation factor of capacitors and of the time constant of resistors by a multi-frequency method is presented. This method is based on the measurement of impedance ratios at two or more frequencies. A bridge is set up with a programmable two-channel ac voltage source and the impedances to be compared. The impedance ratios are determined by synchronous sampling procedures and application of discrete Fourier transform. In a first experiment, a high-grade gas-filled 1-nF standard capacitor was compared with a stable 1-MΩ ac resistor at frequencies between 40 Hz and 660 Hz. The estimated standard uncertainties (k = 1) are 0.7 × 10-6 for the dissipation factor of the capacitor and 0.6 ns for the time constant of the ac resistor.

Zitierung

Ramm, G. & Moser, H. (2004). New multi-frequency method for the determination of the dissipation factor of capacitors and of the time constant of resistors. Conference on Precision Electromagnetic Measurement (CPEM), London, 27, June - 02, July, 2004, UK.

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag