Zugriffsnummer 10686
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel AC power bridge at NMIJ
Autor(in); Institution
Takahashi, K.; National Metrology Institute of Japan (NMIJ/AIST), Tsukuba, Ibaraki, JAPAN
Klonz, Manfred; 2.1, Gleichstrom und Niederfrequenz, PTB-Braunschweig
Bergeest, Rainer; PTB-Braunschweig, retired staff
Takashima, T.; National Metrology Institute of Japan (NMIJ/AIST), Tsukuba, Ibaraki, JAPAN
Quelle/Jahr 2004 Conference on Precision Electromagnetic Measurements Digest:(2004), 295 - 296
ISBN 0-7803-8493-8
Berichtsnummer 04CH37570
Verlag Piscataway, NJ: IEEE
Konferenzangaben Conference on Precision Electromagnetic Measurement (CPEM), London, 27, June - 02, July, 2004, UK
Freie Schlagworte ac power bridge ; NMIJ ; power meters
Zusammenfassung At NMIJ, an accurate ac power bridge was developed to calibrate power meters at 100 V, 5 A, and frequencies from 50 Hz to 120 Hz. This project has been implemented in 2001 due to the master plan of NMIJ.

Zitierung

Takahashi, K., Klonz, M., Bergeest, R., & Takashima, T. (2004). AC power bridge at NMIJ. Conference on Precision Electromagnetic Measurement (CPEM), London, 27, June - 02, July, 2004, UK.

Exportieren

PTB-Publica MenĂ¼