Zugriffsnummer 10464
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Uncertainty of the characteristics of SPRTs calibrated according to the ITS-90
Autor(in); Institution
Fellmuth, Bernd; 7.4, Temperatur, PTB-Berlin
Tegeler, Erich; 7.4, Temperatur, PTB-Berlin
Fischer, Joachim; 7.4, Temperatur, PTB-Berlin
Quelle/Jahr TEMPMEKO 2004, 9th International Symposium on Temperature and Thermal Measurements in Industry and Science: Proceedings: 2 (2005), 1135 - 1140
Herausgeber(in)
Zvizdic, Davor; Faculty of Mechan. Engineering and Naval Architecture, Laboratory for Process Measurement, Zagreb
ISBN 953-6313-73-1
Verlag Zagreb: LPM/ FSB Zagreb Croatia
Konferenzangaben TEMPMEKO 2004 - 9th International Symposium on Temperature and Thermal Measurements in Industry and Science, Cavtat - Dubrovnik, 22-25, June, 2004, Kroatien
Zusammenfassung For the calibration of standard platinum resistance thermometers (SPRTs) usually only the calibration uncertainty at the fixed-points (FPs) is specified. But due to different effects, the uncertainty of the characteristic of an SPRT and thus of ist application by the user is essentially larger than the calibration uncertainty. A complete uncertainty budget is presented considering the uncertainty propagation, the non-uniqueness of the International Temperature Scale and the typical non-repeatability of the SPRT reading.

Zitierung

Fellmuth, B., Tegeler, E., & Fischer, J. (2005). Uncertainty of the characteristics of SPRTs calibrated according to the ITS-90. TEMPMEKO 2004 - 9th International Symposium on Temperature and Thermal Measurements in Industry and Science, Cavtat - Dubrovnik, 22-25, June, 2004, Kroatien.

Exportieren

PTB-Publica MenĂ¼