| Titel | Calibration of dosemeters used in mammography with different X-ray qualities: EUROMET project No. 526 |
| Autor(in); Institution |
Witzani, J.; Bundesamt für Eich- und Vermessungswesen (BEV), Wien, AUSTRIA
Bjerke, H.; Norwegian Radiation Protection Authority (NRPA), Osterås, NORWAY
Bochud, F.; Institut Universitaire de Radiophysique Appliquée (IRA), Lausanne, SWITZERLAND
Csete, I.; Országos Mérésügyi Hivatal (OMH), Budapest, HUNGARY
Denoziere, M.; Laboratoire Central des Industries Electriques (BNM-LCIE), Fontenay-aux-Roses, FRANCE
Vries, W. de; NMi Van Swinden Laboratorium (NMi), Utrecht, THE NETHERLANDS
Ennow, K.; National Institute of Radiation Hygiene (SIS), Herlev, DENMARK
Grindborg, J. E.; Swedish Radiation Protection Authority (SSI), Stockholm, SWEDEN
Hourdakis, C.; Hellenic Ionizing Radiation Calibration Laboratory (HIRCL), Attiki, GREECE
Kosunen, A.; Radiation and Nuclear Safety Authority (STUK), Helsinki, FINLAND
Kramer, Hans-Michael; 6.2, Dosimetrie für die Strahlentherapie, PTB-Braunschweig
Pernicka, F.; International Atomic Energy Agency (IAEA), Vienna, AUSTRIA
Sander, T.; National Physical Laboratory (NPL), Teddington, UK
|
| Quelle/Jahr | Radiation Protection Dosimetry: 108 (2004), 1, 33 - 45 |
| ISSN | 0144-8420 |
| Verlag | Oxford, UK: Oxford Univ. Press |
| Freie Schlagworte | EUROMET comparison ; dosemeters for mammography ; calibration ; energy dependence of response |
| Zusammenfassung | The effect of different X-ray radiation qualities on the calibration of mammographic dosemeters was investigated within the framework of a EUROMET (European Collaboration in Measurement Standards) project. The calibration coefficients for two ionisation chambers and two semiconductor detectors were established in 13 dosimetry calibration laboratories for radiation qualities used in mammography. They were compared with coefficients for other radiation qualities including those defined in ISO 4037-1 with first half value layers in the mammographic range. The results indicate, that the choice of the radiation quality is not crucial for instruments with a small energy dependence of the response. However, the radiation quality has to be chosen carefully, if instruments with a marked dependence of their response to the radiation energy are calibrated. |
Zitierung
Witzani, J., Bjerke, H., Bochud, F., Csete, I., Denoziere, M., Vries, W. D., Ennow, K., Grindborg, J. E., Hourdakis, C., Kosunen, A., Kramer, H.-M., Pernicka, F., & Sander, T. (2004). Calibration of dosemeters used in mammography with different X-ray qualities: EUROMET project No. 526. Radiation Protection Dosimetry, 108(1), 33–45.