Zugriffsnummer 10074
Dokumenttyp Konferenzartikel in Zeitschrift Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel Uncertainty of VNA S-parameter measurement due to non-ideal TMSO or LMSO calibration standards
Autor(in); Institution
Stumper, Ulrich; 2.2, Hochfrequenz und Felder, PTB-Braunschweig
Quelle/Jahr Kleinheubacher Berichte 2002. Advances in Radio Science: 1 (2003), 1 - 8
ISSN 1684-9965 (PRINT) ; 1684-9973 (ONLINE)
DOI
URL
Verlag Darmstadt: U.R.S.I. Landesausschuss in der Bundesrepublik Deutschland e.V.
Konferenzangaben U.R.S.I.-Landesausschuß in der Bundesrepublik Deutschland, Tagung Kleinheubach, Kleinheubach, 01, September, 2002, Germany
Zusammenfassung For the widespread 12-term TMSO and LMSO calibration of 4-sampler vector network analyzers (VNA), the sensitivity coefficients of the S-parameters of two-ports are developed as functions of the deviations of the reflection coefficients of the one-port calibration standards and of an imperfect through or line connection. Expressions representing the deviations of the S-parameters with respect to the error terms and for the deviations of the error terms with respect to the non-ideal calibration standards are also given. It is shown that the deviations of the S-parameters become quite large, particularly for high-reflective two-port test objects. If applying a broadband load (instead of using the time consuming „ideal“ sliding load routine) and the VNA-internal firmware-operated calibration and evaluation routines where the reflection coefficient is set to zero, deviations may appear of some 0,1 dB for the attenuation and some degrees of the transmission phase angle.
Kostenfreier Zugang Open Access Gold
Rechteinformation Creative Commons Attribution-NonCommercial-ShareAlike 2.5 License

Zitierung

Stumper, U. (2003). Uncertainty of VNA S-parameter measurement due to non-ideal TMSO or LMSO calibration standards. Advances in Radio Science, 1, 1–8. https://doi.org/10.5194/ars-1-1-2003

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag