Zugriffsnummer 10040
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Intercomparison exercise of calibration facilities for radon gas activity concentration
Autor(in); Institution
Röttger, Annette; 6.12, Umweltradioaktivität, PTB-Braunschweig
Honig, Anja; 6.12, Umweltradioaktivität, PTB-Braunschweig
Butterweck, G.; Paul Scherrer Institut (PSI), Villigen, SWITZERLAND
Schuler, Ch.; Paul Scherrer Institut (PSI), Villigen, SWITZERLAND
Schmidt, V.; Bundesamt für Strahlenschutz (BfS), Berlin, GERMANY
Buchröder, H.; Bundesamt für Strahlenschutz (BfS), Berlin, GERMANY
Rox, A.; Materialprüfungsamt Nordrhein-Westfalen (MPA), Dortmund, GERMANY
Miles, J. C. H.; National Radiological Protection Board (NRPB), Chilton, UK
Burian, I.; Statni ustav jaderne (SUJCHBO), Milín, CZECH REPUBLIC
Michielsen, N.; Institut de Radioprotection et de Suret.acute. Nucléaire (IRSN) CEA Saclay, Gif-sur-Yvette, FRANCE
Voisin, V.; Institut de Radioprotection et de Suret.acute. Nucléaire (IRSN) CEA Saclay, Gif-sur-Yvette, FRANCE
Maringer, F. J.; ARC Seibersdorf Research GmbH (ARCS), Wien, AUSTRIA
Vargas, A.; Universitat Politècnica de Catalunya (INTE-UPC), Institut de Techniques Energetiques, Barcelona, SPAIN
Quelle/Jahr The natural radiation environment VII : seventh International Symposium on the Natural Radiation Environment (NRE-VII):(2002), 306 - 313
Schriftenreihe Radioactivity in the environment: 7
Herausgeber(in)
McLaughlin, J. P.
ISBN 0-08-044137-8
Verlag Amsterdam [u.a.]: Elsevier
Konferenzangaben 7th International Symposium on the Natural Radiation Environment, Rhodes, 20-24, May, 2002, Greece
Freie Schlagworte intercomparison ; calibration ; radon activity concentration
Zusammenfassung International intercalibration and intercomparison exercises are used as an important tool to provide confidence in the capability of national metrology institutes and calibration laboratories. The quality systems of national institutes provide the basis for running intercomparisons, in our case, in the field of the radon activity concentration in air. Interchange of an electronic radon measuring instrument (intercomparison device) which demonstrated ruggedness during shipping in the past, was considered a convenient means for a relative comparison of radon reference atmospheres. 9 institutes from 7 countries calibrated the intercomparison device according to their quality system at three different extivity concentrations: 1 kBq/m-3, 3 kBq/m-3 and 10 kBq/m-3. The results agreed within 5%, mainly. this is the first step in establishing this intercomparison of the radon activity concentration within scope of Euromet and reaching the quality of a BIPM (Bureau International des Poids et Measures) key comparison later.

Zitierung

Röttger, A., Honig, A., Butterweck, G., Schuler, C., Schmidt, V., Buchröder, H., Rox, A., Miles, J. C. H., Burian, I., Michielsen, N., Voisin, V., Maringer, F. J., & Vargas, A. (2002). Intercomparison exercise of calibration facilities for radon gas activity concentration. 7th International Symposium on the Natural Radiation Environment, Rhodes, 20-24, May, 2002, Greece.